Important customer information: Update to Temporary fuel surcharge.
Find out more.
Hamburger Icon WhiteHamburger Icon
Dulux TradeDulux Trade
Login/Signup
Dulux Trade
  • About Dulux
    Dulux My Home
    Dulux Specifier
    Privacy Policy
    Terms & Conditions
    Careers
  • Customer service
    Contact Us
    Shipping & Returns
    Find a Store
    Sustainability
    Media
    Dulux Group Corporate
  • Dulux in the Community
    Surf Life Saving Club project
About Dulux
Dulux My Home
Dulux Specifier
Privacy Policy
Terms & Conditions
Careers
Customer Service
Contact Us
Find a Store
Sustainability
Dulux Group Corporate
  • © 2026 Dulux

  • Careers
  • Recommended Sites
  • Shipping & Returns
  • Terms & Conditions
  • Privacy Policy
  • Conditions of Sale
Build: 1.2.37 - Fri, 17 Jul 2026 05:24:25 GMT

Dulux Avista

General Purpose Sealer Matt

SALE OFF

No image preview available

SALE OFF

Dulux Avista

General Purpose Sealer Matt

Loader

About Dulux Avista General Purpose Sealer Matt

Dulux Avista Concrete Sealer General Purpose Matt is a solvent based clear sealer which provides a durable protective clear coating for concrete driveways, paths and paved areas

Downloads
Key Points
  • Solvent based
  • Clear matt sealer for external surfaces
  • Good marking resistance
  • Easy to apply
  • Enhances the colour of the surface & provides a wet look appearance
  • Durable sealer for all types of concrete surfaces
  • Helps protect the surface from the ingression of contaminants
Quick guide
close

Touch Dry

1 Hour

Cleaning materials

Dulux Avista solvent

Application Tools

Air Spray, Brush, Roller, Pad, Broom

Product specification
Precautions and limitations
  • The sealed surface should not have foot traffic for at least 24 hours and vehicle traffic for at least 5 days. Do not seal in high winds or if rain is likely.
  • Do not apply over painted surfaces. Paint removal required.
  • Not recommended for internal areas, including garage floors.
  • Not suitable for food preparation areas. Not a waterproofing membrane.
  • Do not seal at temperatures below 8°C or above 30°C.
  • Application of sealer can lower slip resistance (slip resistance additives available)

Important note: Surfaces with a slope of 1:8 (1 metre fall across 8 metres of distance) or greater are not recommended for coating, even with the addition of Dulux Avista Slip Reducing Additive. Contact Dulux Avista for further advice.

Performance guide
  • Weather: Full Acrylic resin with very good resistance to UV light
  • Salt: No visual effect
  • Heat Resistance: Up to 80C
  • Water: No visual effect
  • Solvent:
    • Diesel and oil spills: No visual effect
    • Petrol: expect softening and dulling of surface – immediately clean with detergent and when dry treat with Dulux Avista Solvent
    • Brake Fluid (DOT3): Softening and slight dulling – immediately clean with detergent and when dry treat with Dulux Avista Solvent
  • Abrasion: Suitable for trafficable concrete driveways and paths.
  • Acid: 10% Sulphuric: No visual affect
  • Alkali: 10% Sodium Hydroxide: No visual Effect
Surface preparation
Previously painted surface

Preparation Instructions for New Cured and Old Concrete (unsealed)
Ensure concrete is sufficiently cured (recommended minimum 14 days). Concrete is to be clean and free of grease, oil, paint or any curing agent. Stiff broom and general purpose cleaner recommended. Any oil stains should be treated & cleaned with an industrial degreaser. Pressure clean surface at minimum 2000 psi and allow to dry. Acid etch with hydrochloric acid. Dilute approximately 20 parts water to 1 part acid (depending on porosity) to remove any loosely bound cement and laitance.
Note: Smooth concrete will require a higher acid content. Maximum strength - 10 parts water to 1 part acid.
Apply diluted acid to surface using a large head watering can, applying in a criss cross motion (approximately 5-10m² sections). Acid will start to fizz on the surface once it starts to react with the laitance in the concrete. Pressure clean immediately to clean and remove all remnants of acid (do not allow acid to dry on surface). Pressure clean at minimum 2000 psi. Allow surface to dry before sealing (sealing over damp concrete will cause whitening).
For best results, prime surface using Dulux Avista Pre-Sealer before applying Dulux Avista General Purpose Matt Sealer.

Previously sealed concrete surfaces

A cross hatch test is required if the surface has been sealed more than 2 years ago to ascertain whether existing sealer is suitable to be resealed over.
1. Use a sharp blade to create a light “crosshatch” incision through the sealer.
2. Place a piece of self adhesive tape (suggest clear packing tape) over the incision.
3. Press firmly for maximum adhesion and remove sharply. Repeat with fresh tape several times. If sealer is present on the tape, it is advised the sealer be completely stripped from surface. Seek professional contractors should stripping be required. If there is no sign of sealer adhering to the tape or delaminating from the surface, this would indicate that the bond of the existing sealer is sufficient for resealing.

Important note: If existing sealer shows signs of whitening or blooming, regardless of cross hatch test results, sealer may need to be stripped completely from the surface. Whitening may reoccur if new coat of sealer is applied over this problem.

Cleaning
Concrete is to be clean and free of grease, oil and any other contaminants. A stiff broom and general purpose cleaner are recommended. Pressure clean at minimum 2000 psi to clean and remove all contaminants. Allow surface to dry before resealing (sealing over damp concrete will cause whitening).

Solvent Treatment
If the existing sealer on the surface is surface is more than 2 years old, Solvent is required to reactivate the existing sealer. This will help with the adhesion of the new sealer coat. Apply Dulux Avista Solvent to the area being resealed using a roller and roller tray or broom.

Note: If resealing a resurfaced area, do not apply too much solvent as it may soften the resurfacing product. Complete solvent treatment of entire surface. Allow area to dry enough to walk on before proceeding with sealer application.

How to apply
Brush, Roller

Application Methods
Sealer to be applied by a suitable solvent resistant broom or 11mm-22mm nap roller. Roller used will depend on the profile of the concrete. The sealer must be mixed prior to application using a stirrer or paddle.
To apply sealer, pour sealer into a roller tray, and evenly roll or broom onto the surface.
Ensure sealer is not applied too thick and no pooling occurs as this may cause bubbling.
Avoid excess sealer build up on the edges of the roller. This can lead to roller lines in the surface.
An additional coat of sealer can be applied after a minimum of 2 hours, (recommended recoat 2 hours). For best results, prime previously unsealed surface using Dulux Avista Pre Sealer before applying first coat.

Drying time: Minimum of 2 hours between coats when applied at 25°C and above at 50% relative humidity. Recoat times will be longer in cooler weather (<25°C) or higher humidity. Do not apply sealer at temperatures below 8°C or above 35°C. To obtain a higher slip resistance it is advisable to use the appropriate Slip Reducing Additive with the sealer for better grip under adverse conditions e.g. wet areas, steep slopes and pool surround areas.><25°C) or higher humidity.
Do not apply sealer at temperatures below 8°C or above 35°C.
To obtain a higher slip resistance it is advisable to use the appropriate Slip Reducing Additive with the sealer for better grip under adverse conditions e.g. wet areas, steep slopes and pool surround areas.